{"id":357,"date":"2013-03-10T16:38:20","date_gmt":"2013-03-10T15:38:20","guid":{"rendered":"http:\/\/qualilogy.com\/es\/?p=357"},"modified":"2013-10-13T14:12:03","modified_gmt":"2013-10-13T13:12:03","slug":"instalar-sonar-oracle-loopback-adapter","status":"publish","type":"post","link":"https:\/\/qualilogy.com\/es\/instalar-sonar-oracle-loopback-adapter\/","title":{"rendered":"Instalar Sonar &#8211; Oracle Loopback Adapter"},"content":{"rendered":"<p><a href=\"http:\/\/vicken.deviantart.com\/\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"alignright size-full wp-image-561\" alt=\"Sonar Install - Oracle Loopback Adapter\" src=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/SonarIntall_OracleLoopback.jpg\" width=\"320\" height=\"514\" \/><\/a>El \u00faltimo post de nuestra serie &#8216;Instalar Sonar&#8217; explicaba <a title=\"Instalar Sonar - Oracle\" href=\"http:\/\/qualilogy.com\/es\/instalar-sonar-oracle\/\" target=\"_blank\">la instalaci\u00f3n y la configuraci\u00f3n \u2013 bastante larga \u2013 de Oracle<\/a>.<\/p>\n<p>No tuvimos la oportunidad de ver algunos consejos o trucos que pueden ser \u00fatiles para comprobar que Oracle est\u00e1 instalado y es utilizable.<\/p>\n<p>Si la instalaci\u00f3n se ha realizado en un ordenador de empresa con una conexi\u00f3n de red, entonces Oracle ya debe estar funcionando correctamente.<\/p>\n<p>De hecho, Oracle necesita una direcci\u00f3n IP para poder trabajar. Y sin entrar en detalles, si tu PC est\u00e1 conectado a una red, ya dispones de una direcci\u00f3n IP. Pero si no est\u00e1s siempre (o nunca) conectado a una red corporativa, necesitar\u00e1s una direcci\u00f3n IP local.<\/p>\n<p>Por eso, vamos a instalar un Loopback Adapter, que simula un bucle de red en el ordenador, necesario para utilizar Oracle en una estaci\u00f3n tal como un ordenador port\u00e1til, por ejemplo. <!--more--><\/p>\n<h2>Comprobar si un Loopback Adapter est\u00e1 instalado<\/h2>\n<p>Para eso, abrir una ventana MS-DOS, y introducir el comando <strong>ipconfig \/all<\/strong>.<br \/>\nAqu\u00ed est\u00e1 el resultado en mi ordenador:<\/p>\n<p><a href=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/Ipconfg_All12.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-567\" alt=\"IPCONFIG \/ALL\" src=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/Ipconfg_All12.jpg\" width=\"686\" height=\"363\" \/><\/a><\/p>\n<ul>\n<li>Primero, el nombre de la m\u00e1quina: JPFPC.<\/li>\n<li>Luego un Network Adapter con el nombre \u2018Microsoft Loopback Adapter\u2019 y su configuraci\u00f3n.<\/li>\n<\/ul>\n<p>\u00bfC\u00f3mo se ha creado? Esto es lo que vamos a ver ahora.<\/p>\n<h2>Instalar un Loopback Adapter<\/h2>\n<p>Durante la instalaci\u00f3n, el Loopback Adapater asignar\u00e1 una direcci\u00f3n IP a la m\u00e1quina local.<\/p>\n<p>Lo m\u00e1s probable es que ya tienes una red, o de tu empresa, o simplemente una conexi\u00f3n wifi en casa. Algunos recomiendan ajustar el Loopback Adapter como conexi\u00f3n principal, pero esto no es esencial. Todas las solicitudes se dirigir\u00e1n a la Internet o la red local, excepto herramientas como Oracle Enterprise Manager que utilizan la direcci\u00f3n IP local.<\/p>\n<p>Para continuar con la instalaci\u00f3n, selecciones el men\u00fa &#8216;Start&#8217; de Windows (o la tecla Windows) y escribes <strong>hdwwiz<\/strong> en el campo de b\u00fasqueda de los menus (&#8216;Search&#8217;). El resultado debe devolver un men\u00fa del mismo nombre, que puedes usar para llegar a esta ventana:<\/p>\n<p><a href=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/Add-Hardware-Wizzard-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-573\" alt=\"Install Oracle Loopback - Add Hardware Wizzard screen 1\" src=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/Add-Hardware-Wizzard-1.jpg\" width=\"594\" height=\"435\" \/><\/a><\/p>\n<p>En esta ventana de bienvenida, cliquear el bot\u00f3n &#8216;Next&#8217;. En la pantalla siguiente:<\/p>\n<p><a href=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/Add-Hardware-Wizzard-2.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-574\" alt=\"Install Oracle Loopback Adapter - Add Hardware Wizzard screen 2\" src=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/Add-Hardware-Wizzard-2.jpg\" width=\"594\" height=\"436\" \/><\/a><\/p>\n<p>Seleccionar la opci\u00f3n &#8216;Install the hardware that I manually select from a list&#8217;. De nuevo, &#8216;Next&#8217; para seguir.<\/p>\n<p><a href=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/Add-Hardware-Wizzard-3.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-582\" alt=\"Install Oracle Loopback Adapter - Add Hardware Wizzard screen 3\" src=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/Add-Hardware-Wizzard-3.jpg\" width=\"593\" height=\"436\" \/><\/a><\/p>\n<p>En la lista de tipos de hardware que instalar, seleccionar &#8216;Network adapters&#8217; y de nuevo &#8216;Next&#8217;.<\/p>\n<p><a href=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/Ipconfg_All13.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-577\" alt=\"Install Oracle Loopback Adapter - Add Hardware Wizzar screen 4\" src=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/Ipconfg_All13.jpg\" width=\"594\" height=\"436\" \/><\/a><\/p>\n<p>En esta pantalla, s\u00e9leccionar :<\/p>\n<ul>\n<li>Manufacturer : &#8216;Microsoft&#8217;.<\/li>\n<li>Network Adapter : &#8216;Microsoft Loopback Adapter&#8217;.<\/li>\n<\/ul>\n<p>&#8216;Next&#8217; para seguir y de nuevo &#8216;Next&#8217; cuando Windows est\u00e1 listo para instalar el nuevo hardware (que no es hardware realmente):<\/p>\n<p><a href=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/Add-Hardware-Wizzard-5.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-585\" alt=\"Install Oracle Loopback Adapter - Add Hardware Wizzard screen 5\" src=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/Add-Hardware-Wizzard-5.jpg\" width=\"594\" height=\"435\" \/><\/a><\/p>\n<p>En la pantalla &#8216;Completing the Add Hardware Wizard&#8217;, cliquear el bot\u00f3n &#8216;Finish&#8217;.<\/p>\n<p><a href=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/add-hardware-wizzard-6.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-584\" alt=\"Install Oracle Loopback Adapter - Add Hardware Wizzard screen 6\" src=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/add-hardware-wizzard-6.jpg\" width=\"594\" height=\"435\" \/><\/a><\/p>\n<p>Una vez terminada la instalaci\u00f3n, el bot\u00f3n &#8216;Finish&#8217; permite terminar con este Wizard de instalaci\u00f3n.<\/p>\n<h2>Configurar el Loopback Adapter<\/h2>\n<p>Ahora, vamos a configurar el Loopback. Abrimos el Control Panel, seleccionamos \u2018Network and Internet\u2019, y luego \u2018Network and Sharing Center\u2019.<\/p>\n<p><a href=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/ControlPanel_NetworkCenter.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-575\" alt=\"Install Oracle - Configurer le Loop back Adapter\" src=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/ControlPanel_NetworkCenter.jpg\" width=\"601\" height=\"156\" \/><\/a><\/p>\n<p><a href=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/LocalAreaConnection.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignright size-full wp-image-579\" alt=\"Install Oracle - Configurer le Loop back Adapter\" src=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/LocalAreaConnection.jpg\" width=\"255\" height=\"65\" \/><\/a>En esta ventana, ya tengo una conexi\u00f3n WiFi, y podemos ver una conexi\u00f3n local que corresponde al LoopBack Adapter que acabamos de instalar. Esta conexi\u00f3n puede aparecer con el nombre de &#8216;Local Area Connection 2&#8217; si ya tienes una conexi\u00f3n de red.<\/p>\n<p>Hacemos clic en esta conexi\u00f3n para ver su estado en la siguiente ventana:<\/p>\n<p><a href=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/LocalAreaConnectionStatus.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-571\" alt=\"Install Oracle - Configurer le Loop back Adapter\" src=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/LocalAreaConnectionStatus.jpg\" width=\"378\" height=\"457\" \/><\/a><\/p>\n<p>Cliquear el bot\u00f3n \u2018Properties\u2019 y en la siguiente ventana:<\/p>\n<p><a href=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/LocalAreaConnectionProperties.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-580\" alt=\"Install Oracle Loopback Adapter - Add Hardware Wizzar screen 3\" src=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/LocalAreaConnectionProperties.jpg\" width=\"378\" height=\"475\" \/><\/a><\/p>\n<p>\u2026 seleccionar \u2018Internet Protocol Version 4 (TCP\/IPv4)\u2019.<\/p>\n<p>De nuevo, cliquear el bot\u00f3n \u2018Properties\u2019:<\/p>\n<p><a href=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/IPV4Properties.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-578\" alt=\"Install Oracle - Configurer le Loop back Adapter\" src=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/IPV4Properties.jpg\" width=\"415\" height=\"462\" \/><\/a><\/p>\n<p>Es en esta ventana que podemos configurar nuestro\u00a0Loopback Adapter:<\/p>\n<ul>\n<li>S\u00e9leccionar el radio-bot\u00f3n \u2018Use the following IP address\u2019.<\/li>\n<li>En el campo \u2018IP adress :\u2019, entrar una direcci\u00f3n IP para nuestro Loopback Adapter.<\/li>\n<\/ul>\n<p>Oracle recomienda una direcci\u00f3n no enrutable, es decir, dentro de un espacio de direcciones privadas que permita evitar un conflicto con una direcci\u00f3n IP p\u00fablica. Estas direcciones corresponden con los siguientes rangos de direcciones:<\/p>\n<ul>\n<li>De 10.0.0.0 \u00e0 10.255.255.255.<\/li>\n<li>De 172.16.0.0 \u00e0 172.31.255.255.<\/li>\n<li>De 192.168.0.0 \u00e0 192.168.255.55.<\/li>\n<\/ul>\n<p>Para peque\u00f1as redes dom\u00e9sticas, se utiliza habitualmente el rango de direcciones de 192.168.0.1 hasta 192.168.0.255.<\/p>\n<ul>\n<li>En el campo \u2018Subnet mask\u2019, entrar 255.255.255.0.<\/li>\n<\/ul>\n<p>Guarda el valor que has seleccionado para tu direcci\u00f3n IP: 192.168.254.254 en mi caso.<\/p>\n<p>Selecciona \u2018OK\u2019 para cerrar esta pantalla, luego \u2018Close\u2019 en las otras ventanas.<\/p>\n<h2>El fichero &#8216;hosts&#8217;<\/h2>\n<p>Lo \u00faltimo que se necesita para completar la configuraci\u00f3n de nuestro Loopback Adapter es agregar una entrada correspondiente en el archivo &#8216;hosts&#8217;. Este archivo se encuentra en el directorio &#8216;C:\\Windows\\System32\\drivers\\etc\\&#8217;.<\/p>\n<p>Aqu\u00ed est\u00e1 el mio:<\/p>\n<p><a href=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/HostsFile.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-576\" alt=\"Install Oracle - Configurer le Loop back Adapter\" src=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/HostsFile.jpg\" width=\"561\" height=\"402\" \/><\/a><\/p>\n<p>Puedes ver que he a\u00f1adido una nueva l\u00ednea al final de este archivo con la direcci\u00f3n IP que he elegido para el Loopback Adapter y un nombre de &#8216;host&#8217; que deseo asignar a esta direcci\u00f3n (JPFPC en el ejemplo anterior). Dependiendo de tu sistema operativo, es posible que tengas que reiniciar el equipo.<\/p>\n<p>Para comprobar que todo funciona bien, vamos a hacer un &#8216;ping&#8217; a esta direcci\u00f3n para ver si responde correctamente: En una ventana DOS, entramos el comando &#8216;Ping&#8217; seguido de la direcci\u00f3n (nombre de host o la direcci\u00f3n IP directamente).<a href=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/PingJPFPC.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-572\" alt=\"PingJPFPC\" src=\"http:\/\/qualilogy.com\/fr\/wp-content\/uploads\/sites\/2\/2013\/03\/PingJPFPC.jpg\" width=\"561\" height=\"247\" \/><\/a><\/p>\n<p>En este ejemplo, el comando &#8216;Ping JPFPC&#8217; nos devuelve la direcci\u00f3n IP para nuestro Loopback Adapter.<\/p>\n<p>Hemos terminado con nuestra configuraci\u00f3n. Oracle ahora se pueden ejecutar en un ordenador sin estar conectado a una red.<\/p>\n<p>El pr\u00f3ximo post se centrar\u00e1 de nuevo en consejos y trucos \u00fatiles para Oracle, antes de instalar Sonar.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>El \u00faltimo post de nuestra serie &#8216;Instalar Sonar&#8217; explicaba la instalaci\u00f3n y la configuraci\u00f3n \u2013 bastante larga \u2013 de Oracle. No tuvimos la oportunidad de ver algunos consejos o trucos que pueden ser \u00fatiles para comprobar que Oracle est\u00e1 instalado y es utilizable. Si la instalaci\u00f3n se ha realizado en un ordenador de empresa con [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[],"class_list":["post-357","post","type-post","status-publish","format-standard","hentry","category-sonar-instalacion"],"_links":{"self":[{"href":"https:\/\/qualilogy.com\/es\/wp-json\/wp\/v2\/posts\/357"}],"collection":[{"href":"https:\/\/qualilogy.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qualilogy.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qualilogy.com\/es\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/qualilogy.com\/es\/wp-json\/wp\/v2\/comments?post=357"}],"version-history":[{"count":20,"href":"https:\/\/qualilogy.com\/es\/wp-json\/wp\/v2\/posts\/357\/revisions"}],"predecessor-version":[{"id":774,"href":"https:\/\/qualilogy.com\/es\/wp-json\/wp\/v2\/posts\/357\/revisions\/774"}],"wp:attachment":[{"href":"https:\/\/qualilogy.com\/es\/wp-json\/wp\/v2\/media?parent=357"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qualilogy.com\/es\/wp-json\/wp\/v2\/categories?post=357"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qualilogy.com\/es\/wp-json\/wp\/v2\/tags?post=357"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}